Supply Duct; Return Duct - Nordyne P5RF-X48K User Manual And Installation Instructions

15 seer 2-stage r-410a single package air conditioner
Table of Contents

Advertisement

4. INSTALLTH
E RETU RN AN D SU PPLY AIR
FITTINGS ON THE UNIT
The supply and return fittings are included with
select models. If supplied, the duct fittings are
shipped in the supply duct.They attach to the unit
openings with a flange and bead arrangement,
secured with two sheet metal screws. Note: For
ease of access, install fitting before positioning
unit in final location.
SUPPLY DUCT
Position the supply duct collar, if supplied, so the
edge of the unit opening fits between the flange
and the bead. Overlap the collar ends keeping the
small screw holes underneath. Align the holes in
the crimped area and install one screw.
Note: It may be necessary to loosen the four
screws that hold the transition duct in order to
install the supply fitting. Re-tighten when instal-
lation is complete.
Tap collar as necessary to ensure engagement
with
unit opening
and install second
screw.
Tighten first screw. Rotate collar clockwise so
joint is near three o'clock position.
RETURN DUCT
Align the 14" return duct slots with the holes in
the collar and install two screws. Position the
collar over the opening and align the four notches
in the collar with the four dimples in the panel.
Using self-drilling
screws (10-16x.5)attach
the
collar to the rear panel.
5.
LOCATING
AND INSTALLING THE RE-
TURN AIR ASSEMBLY
To avoid complications,
locate and install the
return air assembly
first. The return air box
with grille and filter (Figure 4) should not be
located in heavy traffic areas like hallways or
center of rooms. A good spot is in a corner or
under a table, if a minimum two inch clearance
is available. If desired, the return opening can
be located inside a closet with Iouvered doors
that have an open area equal to or greater than
the 12" x 20" grille furnished. The return air grille
can be placed in the wall of a closet and the air
ducted into the filter box through a boxed-in area
at the closet floor level. Make sure the filter is
readily accessible.
After determining
the location of the return air
opening, start the installation
from under the
home by cutting a small hole in the fiber under-
board to determine how the floor joist location
will affect cutting the opening needed for the box.
Floor joists generally are located on 16" centers,
leaving 14-3/8" between joists. After measuring
REG[STER
Figure 5. Supply
Damper
the return air box (approximately
12-1/4" x 14-
1/4"), cut the hole through the floor so that the
box will fit between the floor joists. Care should
be taken when cutting through carpeting to avoid
snags. In most installations itwill be necessary to
cut a similar hole in the fiberboard directly under
the hole in the floor. However, if the floor is more
than ten inches deep, it will only be necessary
to cut a hole for the collar on the return air box
or for the insulated duct.
Set the box into the opening and fasten with
screws or nails. Put the filter and return air
grille in place.
6,
LOCATING
AND
INSTALLING
THE
SUPPLY DAMPER(S)
CAUTION"
When
a home
is not equipped
with
a
make-ready
kit, means
must
be pro-
vided
to prevent
simultaneous
opera-
tion of the
heating
and
cooling
units.
A heat/cool
thermostat
is available
for
this purpose.
When
installing this air conditioning
system in conjunction with a furnace, a
damper must be installed in the furnace
base assembly to prevent cold air being
discharged around the heat exchanger.
Damage
to the heat exchanger
and
asphyxiation
may occur if a damper is
not installed.
Check with the furnace
manufacturer
for damper
requirements.
Failure to
install
the required
furnace
damper
may invalidate code agency listing and
limited warranty on the furnace.
When locating the supply damper(s), carefully
check floor joists and frame members that could
interfere with the installation of the damper or
flexible duct. Ideally, the damper
should
be