SECTION 1.
OWNER INFORMATION
OPERATING
INSTRUCTIONS
To OperateYour Air Conditioner for Cooling--
Thermostat
-- The 15 SEER Air Conditioner
uses a special two speed com pressor to achieve
a high level of efficiency in a compact frame. A
two stage cooling 24VAC thermostat
can be
used with these units. For the highest efficiency
the use of a two-stage
cooling thermostat
is
recommended.
Refer to Figure 11 or 12 for a
unit wiring diagram.
Cooling Mode:
1.
On a call for cooling the thermostat closes,
applying 24VAC to the G and Y1 terminals
on the control. This closes the compressor
contactor, and the compressor operates on
1st stage.
2.
If the thermostat
is not satisfied in the
required time, based on the operation of
the two-stage cooling thermostat, Y2 will
System
Fan
Temperature
Mode
Mode
Selector
Figure 1. Typical Thermostat
3.
energize and the compressor
will run at
second
stage.
Refer to the thermostat
installation
instructions
for the cooling
profile.
When the thermostat
is satisfied,
the G
and Y terminals
on the control board are
de-energized
opening
the compressor
contactor.
ToOperateYour
Unit for Heating--(Ifoptional
heat accessory
is installed.)
1. Set the thermostat system switch to HEAT or
AUTO and the thermostat fan switch to AUTO.
(See Figure 1)
2. Set the thermostat temperature to the desired
temperature level using the temperature selector.
Please refer to the separate user's manual for
complete thermostat programming
instructions.
The indoor
blower will cycle on and off to
maintain the indoor temperature at the desired
heating level.
To Shut Off Your Air Conditioner
--Set
the
thermostat
system
switch
to OFF and the
thermostat fan switch to AUTO. (See Figure 1 )
The system will not operate, regardless of the
thermostat temperature setting.
To Operate the Indoor Blower Continuously--
Set the thermostat fan switch to ON (See Figure 1)
The indoor blower will start immediately,
and
will run continually
until the fan switch is reset
to AUTO.
The continuous indoor blower operation can be
obtained with the thermostat system switch set
in any position, including OFE The continuous
indoor
blower operation
is typically
used to
circulate the indoor air to equalize a temperature
unbalance due toa sun load, cooking, or fireplace
operation.
BEFOREYOU
CALL A SERVICEMAN
Let your serviceman
check your system at the
start of each air conditioning
season.
He will
make sure it's working right, clean or change
filters and make any needed adjustments.
In addition,
follow these simple rules:
1.
Never run your system without filter. If you
do, the cooling coils will get dirty and may
become clogged.
2.
Set your thermostat at the comfort level you
wish -- and then leave it alone. Let it control
the operation of the air conditioning system.
If you get chilly, turn it up a degree at a time
until comfort is restored.
3.
It takes longer for an air conditioner to cool
yourdwelling than it does for your furnace to
heat it.Therefore, do not turn the unit on and
expect a dramatic drop in temperature,
at
least not right away. If your home is hot and
humid, the temperature will drop slowly.
4.
Check yourfilters every ten days in summer
to see if they are dirty. To keep them clean,
use a mild solution of detergent and water
on washable types. Replace non washable
filters.
5.
Keep your outdoor condenser coil clean.
You can hose it down when it gets dirty.
If your air conditioner
isn't working:
1.
Make sure the fuses are not blown or that
your circuit breakers are on.
2.
See that your thermostat is set at the desired
temperature and that your system's switch
is on "Cool."