Planning - Craftsman 139.53964SRT Owner's Manual

1/2 hp
Table of Contents

Advertisement

Available languages

Available languages

Planning
Identify the type and height of your garage door.
Survey your garage area to see if any of the
conditions below apply to your installation. Additional
materials may be required. You may find it helpful to
refer back to this page and the accompanying
illustrations as you proceed with the installation of
your opener.
Depending on your requirements, there are several
installation steps which may call for materials or
hardware not included in the carton.
• Installation Step 1 - Look at the walt or ceiling
above the garage door. The header bracket must
be securely fastened to structural supports.
• Installation Step 5 - Do you have a finished ceiling
in your garage? If so, a support bracket and
additional fastening hardware may be required.
• Installation Step 10 - Depending upon garage
construction, extension brackets or wood blocks
may be needed to install sensors.
• Installation Step 10-Alternate
floor mounfing of
the safety reversing sensor will require hardware
not provided.
Do you have an access door in addition to the
garage door? If not, Model 53702 Emergency Key
Release is required. See Accessories
page.
Look at the garage door where it meets the floor.
Any gap between the floor and the bottom of the
door must not exceed 1/4" (6 mm). Otherwise, the
safety reversal system may not work properly. See
Adjustment Step 3. Floor or door should be
repaired.
SECTIONAL DOOR INSTALLATIONS
Do you have a steel, aluminum, fiberglass or glass
panel door? If so, horizontal and vertical
reinforcement is required (Installation Step 11).
The opener should be installed above the center of
the door. If there is a torsion spring or center
bearing plate in the way of the header bracket, it
may be installed within 4 feet (1.22 m) to the left or
right of the door center. See Installation Steps 1
and 11.
• If your door is more than 7 feet (2.13 m) high, see
rail extension kits listed on Accessories page.
SECTIONAL DOOR INSTALLATION
Horizontal and vertical reinforcement
is needed for lightweight
garage doors
(fiberglass,
steel, aIuminum, door with
glass panels, etc.). See page 24 for details.
Header Wall
Rail
Extension Spring
OR
f
Torsion Spring
FINISHED CEILING
SuppoA bracket&
ravening
hardware
is required.
See page 17
Motor unit
Wail-
mounted
Door
Control
Access
Door
O
Safe,
Reversing Sensor
Gap between floor
and bottom of door
must not exceed 1/4" (6 ram)
Safety
Reversing
Sensor
eader
/all
arage
oor
CLOSED
POSITION
Header
Bracket
Tr011ey
Stop Bolt
Trolley
Garage
Door
Spring
Belt
Emergency
Release
Rope & Handle
Curved
Door
Arm
Bracket
4

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents