HP Surestore Disk Array 12h - And FC60 Service Manual page 169

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Event
Event Name
Number
(DEC/hex)
Internal SCSI
170/0xaa
Reassign
Completed
Internal SCSI
171/0xab
Reassign
Canceled
No Error On
172/0xac
Disk Media
After Medium
Error
Incompatible
173/0xad
RAM Image
Revision
Event
Predictive
Logged
Maintenance
Implication
Y
See disk drive
vendor's
reassign rate
spec.
Y
Ignore
Ignore unless
Y
medium error
recurs
Y
Ignore -
Operator Error
Event Code Descriptions
Suspected
Description
Components
Disk Drive
The controller successfully
completed a sparing operation.
The reported FRU is the slot
number.
None
A sparing operation was
canceled, typically due to a
hog plug event on the bus. The
sparing operation will not be
retried until another the bad
block is accessed again. The
reported FRU is the slot
number.
Disk Drive
The controller has determined
that media for which a disk
drive had reported a
MEDIUM ERROR is actually
OK. The data stored at the
affected block may or may not
have been recovered. The
reported FRU is the slot
number.
None
The NVRAM image stored on
the disk set when it was
shutdown is not compatible
with the current version of
controller firmware. This is
typically caused when
upgrading controller firmware.
Returning to the previous
firmware revision will correct
this problem without data loss.
Troubleshooting
169

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents