HP Surestore Disk Array 12h - And FC60 Service Manual page 162

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Disk Drive
144/0x90
Installed
Disk Drive
145/0x91
Added To Disk
Set
162
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore -
Operator
Activity
Ignore -
Y
Operator
activity
Suspected
Description
Components
None
The controller has detected the
installation of a new disk
drive. This event occurs
regardless of the disposition of
the drive toward the disk set.
The disk drive ID number
assigned to the drive installed
appears in the component
identifier field of this log
entry. A disk drive ID number
consisting of the controller
serial number followed by a 0
indicates that the disk drive ID
number has not yet been
assigned.
None
The controller has included a
new disk drive in the disk set.
This event occurs only when a
disk drive that was not
previously a member of the
disk set becomes a member. It
does NOT occur when a
down, failed, or missing disk
is returned to ready status.
The disk drive ID number
assigned to the drive added
appears in the component
identifier field of this log
entry.