HP Surestore Disk Array 12h - And FC60 Service Manual page 143

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Event
Event Name
Number
(DEC/hex)
Illegal Drive
36/0x24
State For Down
Command
Recovered With
37/0x25
RAID 5 Retries
Recovered With
38/0x26
RAID 5
Redundancy
Unavailable
39/0x27
Data Detected
By RAID 5
Send Diagnostic
40/0x28
Self Test Failure
Invalid Pass
41/0x29
Through
Event
Predictive
Logged
Maintenance
Implication
N
NA
Y
Ignore - See
accompanying
errors
Y
Ignore - See
accompanying
errors
Y
See
Accompanying
Errors
N
Single
Occurrence
N
NA
Event Code Descriptions
Suspected
Description
Components
None
An attempt to down a disk
failed. Downing the disk
would have resulted in loss of
redundancy or data
unavailability. Make sure the
correct down type is specified
when performing the
command.
None
Retries were used successful
completion of a read or write
to RAID 5 space.
None
Redundancy was used in the
successful completion of a
read or write to RAID 5 space.
None
An attempt to read or write
failed because the array is in
a data unavailable state. This
may be a result of removing
disk drives. Reinstall any
disks that may have been
removed.
Controller
The current system state and
warnings indicate that the self
test should return bad status.
Check system state and
warning states for more
information.
None
The host attempted an execute
pass through command
without a valid Set Pass
Through Mode command
preceding.
Troubleshooting
143

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents