Event
Event Name
Number
(DEC/hex)
Disk Drive
146/0x92
Removed
Disk Drive
147/0x93
Deleted From
Disk Set
Logical Unit
148/0x94
Created
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore unless
no operator
activity
Y
Ignore -
operator
activity or
associated
errors
Ignore -
Y
operator or
host activity
Event Code Descriptions
Suspected
Description
Components
Disk Drive
The controller has detected
Internal SCSI
that a disk drive has been
Bus
removed. This event occurs
Controller
for disk set members only.
The disk drive ID number
assigned to the drive removed
appears in the component
identifier field of this log
entry. A disk drive ID number
consisting of the controller
serial number followed by a 0
indicates that the disk drive ID
number has not yet been
assigned.
None
The controller has deleted a
disk set member. This occurs
only when a drive that was
previously a member becomes
a non-member. The drive may
or may not be present in the
disk array at the time.
The disk drive ID number
assigned to the drive deleted
appears in the component
identifier field of this log
entry.
None
The controller has
successfully created a new
LUN. The component
identifier field of this log entry
contains the number of the
new LUN (first 8 bytes) and
its capacity (last 8 bytes).
Troubleshooting