Event
Event Name
Number
(DEC/hex)
Unable To
153/0x99
Recreate
Memory Error
Memory Error
154/0x9a
Not Recovered
With
Redundancy
Memory Error
155/0x9b
Recovered With
Redundancy
Uncorrectable
156/0x9c
Memory Error
Correctable
157/0x9d
Memory Error
Memory
158/0x9e
Compare Error
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore
Y
More than 1
in 6 mo.
Y
Ignore - See
accompanying
errors
Y
More than 1
in 6 months
per controller
Y
See correctable
rate associated
with usage
page
Ignore - See
Y
accompanying
errors
Event Code Descriptions
Suspected
Description
Components
None
The controller experienced a
memory error but was unable
to recreate the failed memory
accesses. The disk array will
reset in response to this
condition. A reset will rescan
all memory and attempt to
locate the problem.
SIMM
The controller experienced an
Controller
unrecoverable error that could
Backplane
not be recovered using
redundant memory. This may
cause data loss if the error
occurs in non-redundant
NVRAM memory..
None
The controller experienced an
unrecoverable error that was
recovered using redundant
memory, or a controller reset
SIMM
The controller experienced an
Controller
uncorrectable memory error
Backplane
ECC error.
SIMM
The controller experienced a
Controller
correctable error.
Backplane
SIMM
The system experienced a
Controller
compare error between the
Backplane
redundant memories. The
mirrored image maintained by
the two controllers does not
match, but the exact cause is
not apparent.
Troubleshooting