2.3 Power Supply Troubleshooting
S3V output (P60)
Error code
40h
45h
46h
E5V output (P61)
Error code
50h
51h
52h
54h
E3V output (P62)
Error code
60h
61h
62h
64h
1R5-E1V output (P63:CH0)
Error code
70h
71h
72h
TECRA M5 Maintenance Manual (960-542)
S3V voltage is 3.47V or less when the computer is powered on/off.
S3V voltage is 3.14V or less in normal conditions.
S3V voltage is 3.14V or less at power on.
E5V voltage is over 6.00V when the computer is powered on/off.
E5V voltage is 4.50V or less in normal conditions when the computer
is powered on.
E5V voltage is 4.50V or less at power on.
E5V voltage is 4.50 V or less when EV is maintained and "OUTV1
power = EV power" is specified.
E3V voltage is over 3.96V when the computer is powered on/off.
E3V voltage is 2.81V or less in normal conditions when the computer
is powered on.
E3V voltage is 2.81V or less at power on.
E3V voltage is 2.81 V or less when EV is maintained and "OUTV2
power = EV power" is specified.
1R5-E1V voltage is over 1.80V when the computer is powered on/off.
PPV voltage is 0.56V or less in normal conditions when the computer
is powered on.
PPV voltage is 0.56V or less at power on.
[CONFIDENTIAL]
2 Troubleshooting Procedures
Meaning
Meaning
Meaning
Meaning