3.20 ONLY ONE TEST
Subtest 05
USB
NOTE: When executing this subtest, USB test module and USB cable must be connected.
This subtest checks if USB port works properly.
The following menu appears in the display.
################################################################
########
################################################################
*
*
0 ............
*
1 ............
*
9 ............
*
****************************************************************
.... Press test number[0-1, 9] ?
Connect the USB test module and USB cable to the computer.
Input the port test number and press Enter.
OK message appears in the display if the test ends without fail.
NG message appears in the display if an error is found during the test.
Confirm the connection of cable, and then execute the test again.
Press 9 and Enter to return to ONLY ONE TEST menu.
Subtest 06
Docker Dock/Undock
This subtest is executed with an Advanced Portreplicator III Plus installed.
Press Enter while pushing the eject button of the Advanced Portreplicator III
Plus after the following message appears.
Slide Eject-SW, and press [Enter] Key
Press Enter without pushing the eject button of the Advanced Portreplicator
III Plus after the following message appears.
Release Eject-SW, and press [Enter] Key
If the test ends successfully, the display returns to the ONLY ONE TEST
menu.
When the display returns to the ONLY ONE TEST menu, remove the
Advanced Port Replicator III Plus from the computer.
TECRA M5 Maintenance Manual (960-542)
ONLY ONE TEST Menu (XXXXXXXXX)
Port 0 (Left side)
Port 1 (Right side front)
EXIT 2 (Right side back)