Elbow For Straight Horizontal Terminations; Venting Arrangements - HAMPTON BAY Hampton H35-NG2 Owners & Installation Manual

Direct vent gas fireplace
Hide thumbs Also See for Hampton H35-NG2:
Table of Contents

Advertisement

INSTALLATION
ROTATING 45
1) Remove all 4 screws that secure
the elbow to the unit using a 1/4"
magnetic nut driver.
Remove all 4 screws
and washers
Horizontal Terminations for All
Venting Systems
The shaded areas in the diagram below show
all allowable combinations of vertical runs with
horizontal terminations. Maximum one 90
o
elbow (two 45
elbows equal one 90
All approved caps listed on page 12 - may
be used.
Propane and Natural Gas:
Residential, Manufactured and
Mobile Homes Installations
The venting arrangements diagrammed below,
have a min. of 75% (fl ue loss) effi ciency with Fan
Off, as required for manufactured homes. (Actual
effi ciency may be as high as 85%)
May be installed in Manufactured (Mobile)
Homes after fi rst sale.
NOTE: See "Vent Restrictor Position" section for
installation instructions for the Vent Restrictor
Position.
16
O

ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS

VENTING ARRANGEMENTS

The shaded area in the diagram below shows all allowable combinations of straight vertical and
offset to vertical runs with vertical terminations. Maximum two 45
O
o
elbow).
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.
2) Rotate the elbow 180
3) Secure the elbow by securing
it with the 4 screws.
Vertical Terminations Systems for
Residential Manufactured and Mobile Homes
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Offset to Vertical Terminations
Hampton® H35-2 Direct Vent Freestanding Gas Stove
o
o
elbows.