HAMPTON BAY Hampton H35-NG2 Owners & Installation Manual page 19

Direct vent gas fireplace
Hide thumbs Also See for Hampton H35-NG2:
Table of Contents

Advertisement

One 90
Option V
A)
1' Min.
3' Max. 2' Min.
B)
2' Min.
4' Max. 3' Min.
C)
3' Min.
5' Max. 4' Min.
D)
4' Min.
6' Max. 5' Min.
E)
5' Min.
7' Max. 6' Min.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the "Vent Re-
strictor Position" section.
o
One 90
Option
H + H1
A)
2' Max.
B)
3' Max.
C)
4' Max.
D)
5' Max.
E)
6' Max.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the
"Vent Restrictor Position" section.
Hampton® H35-2 Direct Vent Freestanding Gas Stove
Vertical Venting with Two (2) 90
o
o
elbow = Two 45
elbows.
H
V + V1
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
7 feet total horizontal.
Please note min. 1 foot
between 90
required.
Vertical Venting with Two (2) 90
o
elbow = Two 45
elbows.
V
With these options, max. total
2' Min.
pipe length is 30 feet with min.
of 6 feet total vertical and max.
3' Min.
6 feet total horizontal.
4' Min.
Please note min. 1 foot
5' Min.
o
between 90
elbows is
6' Min.
required.
o
o
elbows is
o
V
H1
INSTALLATION
Elbows
Elbows
H
19