INSTALLATION
o
One 90
elbow = Two 45
Option
V
H + H1
A)
3' Min.
2' Max.
B)
4' Min.
3' Max.
C)
5' Min.
4' Max.
D)
6' Min.
5' Max.
E)
7' Min.
6' Max.
F)
8' Min.
8' Max.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the
"Vent Restrictor Position" section.
One 90
o
elbow = Two 45
Option
H
V
A)
1' Max.
2' Min.
B)
2' Max.
3' Min.
C)
3' Max.
5' Min.
D)
4' Max.
7' Min.
E)
5' Max.
9' Min.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the "Vent
Restrictor Position" section.
18
Horizontal Venting with Two (2) 90
o
elbows.
With these options, maxi-
mum total pipe length is 30
feet with minimum of 8 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
Horizontal Venting with Two (2) 90
o
elbows.
With these options, max.
H + H1
total pipe length is 30 feet
3' Max.
with min. of 9 feet total
5' Max.
vertical and max. 8 feet
6' Max.
total horizontal.
Please note min. 1 foot
7' Max.
o
between 90
elbows is
8' Max.
required.
o
Elbows
o
Elbows
V
Hampton® H35-2 Direct Vent Freestanding Gas Stove