Safety Label; Copy Of Safety Label - HAMPTON BAY Hampton H35-NG2 Owners & Installation Manual

Direct vent gas fireplace
Hide thumbs Also See for Hampton H35-NG2:
Table of Contents

Advertisement

This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove.
We have printed a copy of the contents here
for your review.
FACTORY EQUIPPED FOR NATURAL GAS
FACTORY EQUIPPED FOR PROPANE GAS
Minimum Clearances to Combustibles/Degagement
Minimum De Materiaux Combustibles
Minimum ceiling height from top of unit:36"/914mm
Minimum plafond hauteur en haut de l'appareil:
A 6-1/2"/165mm
B 6"/152mm
Minimum clearance of Vent Terminal to Outside Corner & Inside Corner:
with AstroCap 6"/150mm with Dura-Vent Cap 12"/300mm
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas
and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCS-
BCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, Na-
tional Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24
CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCS-
BCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifi ée est fournie.
This vented gas fi replace heater is not for use with air fi lters.
For use with glass doors certifi ed with the appliance only
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE
FPI Fireplace Products International Ltd. Delta, BC, Canada
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas appliance is installed.
Hampton® H35-2 Direct Vent Freestanding Gas Stove

COPY OF SAFETY LABEL

Listed: VENTED GAS FIREPLACE HEATER /
FOYER AU GAZ À ÉVACUATION
Certifi ed for/Certifi ée pour: CANADA and U.S.A.
WN# 16478
Tested to: CGA 2-17-M91, ANSIZ21.88a-2007/CSA 2.33a-2007
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
Model:H35-NG2
Minimum supply pressure
5"
WC/C.E. (1.25 kPa)
Manifold pressure High
3.8" WC/C.E. (0.94 kPa)
Manifold pressure Low
1.1" WC/C.E. (0.27 kPa)
Maximum Input
36,000 Btu/h (10.55 Kw/h)
Minimum Input
18,000 Btu/h (5.28 Kw/h)
Orifi ce size
#33 DMS
Altitude
0-4500 ft/pi (0-1372m)
Convertible to 30,000
Orifi ce Size
#37 DMS
Maximum Input
30,000 Btu/h (8.78 Kw/h)
Minimum Input
14,300 Btu/h (4.19 Kw/h)
Altitude
0-4500 ft/pi (0-1372m)
Model:H35-LP2
Minimum supply pressure
12"
WC/C.E. (3.00 kPa)
Manifold pressure High
11" WC/C.E.
Manifold pressure Low
2.9" WC/C.E. (0.72 kPa)
Maximum Input
34,000 Btu/h (9.97 Kw/h)
Minimum Input
17,500 Btu/h (5.13 Kw/h)
Orifi ce size
#51 DMS
Altitude
0-4500 ft/pi (0-1372m)
Convertible to 28,500 Btu
Orifi ce Size
#52 DMS
Maximum Input
28,500 Btu/h (8.35 Kw/h)
Minimum Input
15,000 Btu/h (4.39 Kw/h)
Altitude
0-4500 ft/pi (0-1372m)
C 2" / 50mm
E 2"/50mm
DUPLICATE SERIAL NO.
DO NOT REMOVE THIS LABEL / NE
PAS ENLEVER CETTE ÉTIQUETTE
ÉQUIPÉ A L'UISINE POUR GAZ NATURAL
Pression d'allimentation minimum
Pression à la tubulure d'échappement élevée
Pression à la tubulure d'échappement basse
Débit Calorifi que maximum
Débit Calorifi que minimum
(2.87mm)
Dimensions de l'orifi ce
L'altitude
Dimensions de l'orifi ce
Débit Calorifi que maximum selon
Débit Calorifi que minimum selon
L'altitude
ÉQUIPÉ A L'UISINE POUR GAZ PROPANE
Pression d'allimentation minimum
(2.74 kPa)
Pression à la tubulure d'échappement élevée
Pression à la tubulure d'échappement basse
Débit Calorifi que maximum
Débit Calorifi que minimum
(1.70mm)
Dimensions de l'orifi ce
L'altitude
Dimensions de l'orifi ce
Débit Calorifi que maximum selon
Débit Calorifi que minimum selon
L'altitude
Left Side Wall
Left Side Wall
A
B
Vertical
Horizontal
Pipe
Pipe
A
Right Side Wall
Right Side Wall
Ne pas utiliser de fi ltre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifi ées avec l'appareil
Made in Canada/Fabrique au Canada

SAFETY LABEL

®
NOTE: Hampton
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
355
355
Serial No./ No de serie
A
E
C
E
A
918-840
5