FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
4. Loosen the bolts securing the valve and bracket
assembly then remove the screws securing the
valve to the bracket.
5. Reverse the procedure to install the replacement
gas valve.
NOTE: Clean the pipe threads and apply pipe joint
compound to threads. Any pipe joint compound
used, must be resistant to the action of propane
gases.
6. Verify gas pressure as outlined under GAS
PRESSURE ADJUSTMENT in SERVICE
PROCEDURES AND ADJUSTMENTS and check
for proper operation.

IGNITION CONTROL MODULE

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
1. Remove the right side panel as outlined under
COVERS AND PANELS.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the control
panel as outlined under COVERS AND PANELS.
2. Loosen the screws securing the mounting bracket
to the component panel and remove the bracket.
F32700 (February 2006)
3. Disconnect the lead wires and igniter cable from
the ignition module board.
4. Remove the ignition module board from the
mounting bracket.
5. Reverse the procedure to install the replacement
ignition module board.
SPARK IGNITER AND
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
1. Remove the gas burner as outlined under GAS
BURNER.
2. Remove the screws securing the ignitor and
flame sense to burner then remove the assembly.
Page 10 of 64
FLAME SENSE
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.