V SERIES FOOD HOLDING, TRANSPORT, AND BANQUET CARTS
3.
Remove the old door.
may need to open the latch.
4.
Remove the phillips head screws
that attach the latch to the door.
Note: There may be anywhere
from two (2) to four (4) screws on
the latch.
5.
If necessary, drill the new holes
using a #19 drill bit (or 11/16" bit.)
Note:
When drilling holes into
the cabinet frame, use a long drill
bit (2") as you need to drill
through both sides of the 1"
frame tubing.
6.
Apply a thread locker material to
any screw/screws you are re-
installing.
7.
Using a screw gun, attach the
door to the hinge and latch to the
door.
8.
Close the door and check for
gaps between the door and
gasket.
Adjust as necessary.
Adjust the latch, if necessary.

DOOR GASKET

Before removing the old gasket, verify
that the replacement gasket(s) are the
correct size and length.
To obtain Service and Parts information concerning this model, contact Vulcan-Hart Service Department
at the address listed on the front cover of this manual or refer to our website:
a complete listing of Authorized Service and Parts depots.
Customer Service
Technical Service
Service Parts
When calling for service, have the model number and serial number available
You
1.
2.
3.
4.
5.
6.
SERVICE & PARTS INFORMATION
1-800-814-2028
1-800-814-2028
1-800-814-2028
14
Remove the old gasket by pulling
it out of the aluminum J-channel.
Verify
that
all
gasket
adhesive has been completely
removed before proceeding to
step 3.
Install the new gasket by starting
at one end and pressing the
gasket into the J-channel.
slotted screw driver may be
needed to fully seat the gasket.
You can also use "Pam Cooking
Spray."
Note: Be careful not to puncture
the gasket with the screw driver.
Repeat until all gaskets have
been replaced.
Using a "food grade" sealant /
adhesive, seal the corners
eliminate any gaps,
prevent the gasket from sliding
in the J-channel.
Wipe away any excess sealant.
Note: Allow 30 minutes for the
sealant / adhesive to cure.
When the sealant/adhesive has
cured, close the door and check
for gaps between the door and
gasket.
Adjust
the
extusion, if necessary.
www.vulcanhart.com