Operation; Controls; Lighting Instructions; Grid Position And Gas Setting - Vulcan-Hart VRB Series Installation & Operation Manual

Vrb and vir series top fired broilers
Table of Contents

Advertisement

WARNING:
THE BROILER AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING,
CLEANING OR SERVICING THE BROILER.

CONTROLS

Gas Valves
— Regulate gas flow to the burners.
Elevator Lever — Use elevator lever on the right to position the grill in relation to the burner heat.
Grease Drawer — Collects grease from broiled food.

LIGHTING INSTRUCTIONS

1. Turn the gas shut-off and gas valves to the OFF position and wait 5 minutes.
2. Turn gas shut-off valve ON and light two pilots with a lit taper. Adjust until the pilot flame is
(6 mm) high. The flame should have a slight yellow tip. Pilot valves are behind the plug button
on the right panel.
3. The only adjustment needed may be the air shutter located at the front face of the burner where
the orifice enters the venturi. Adjust all traces of yellow out of the burner flame.
4. To relight, follow steps 1-3.

GRID POSITION AND GAS SETTING

Each operator will find the optimum grid position and gas setting for various products; however, it is
recommended that gas input be reduced first when lower grid temperatures are desired. Further
reduction in grid temperatures, if necessary, can then be adjusted by lowering the grid position.

PREHEATING

Allow broiler to preheat approximately 30 minutes with burners full-on. Rub grates with grease before
using. The excess grease will run forward and drip onto the front grease drawer.

OPERATING VRB36 SERIES MODELS

1. Load broiler.
2. Turn gas valve to the left (counterclockwise) as far as the knob will go.
3. When the burner lights, turn the knob to the right (clockwise) until the flame is the desired height.

OPERATING VIR36 SERIES MODELS

1. Turn valves full ON to light.
2. Do not adjust lower than one-half flame.

SHUTDOWN

1. For complete shutdown, turn gas and shut-off valves to the OFF position.
2. Turn pilot adjustment valve fully closed until gas stops flowing.

OPERATION

– 7 –
1
/
"
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vir seriesVrb36Ml-44953zVrb36cMl-44954zVrb36m ... Show all

Table of Contents