Vulcan-Hart VRB Series Installation & Operation Manual

Vulcan-Hart VRB Series Installation & Operation Manual

Vrb and vir series top fired broilers

Advertisement

Quick Links

VRB AND VIR SERIES TOP FIRED BROILERS
MODELS
VRB36
VRB36C
VRB36M
VRB36S
VRB36F
VRB36FM
VRB36FC
VRB36FS
VIR36
VIR36C
VIR36M
VIR36S
VIR36F
VIR36FM
VIR36FC
VIR36FS
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791
FORM 31168 (Jan. 2001)
ML-44953Z
ML-44954Z
ML-44959Z
ML-44955Z
ML-44956Z
ML-44960Z
ML-44957Z
ML-44958Z
ML-44947Z
ML-44948Z
ML-44961Z
ML-44949Z
ML-44950Z
ML-44962Z
ML-44951Z
ML-44952Z
INSTALLATION &
OPERATION MANUAL
– 1 –
Model VIR36FS
www.vulcanhart.com

Advertisement

Table of Contents
loading

Summary of Contents for Vulcan-Hart VRB Series

  • Page 1 ML-44957Z VRB36FS ML-44958Z VIR36 ML-44947Z VIR36C ML-44948Z VIR36M ML-44961Z VIR36S ML-44949Z VIR36F ML-44950Z VIR36FM ML-44962Z VIR36FC ML-44951Z VIR36FS ML-44952Z Model VIR36FS VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 31168 (Jan. 2001) – 1 – www.vulcanhart.com...
  • Page 2 CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE. © VULCAN-HART COMPANY, 2001 – 2 –...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS GENERAL............... 4 INSTALLATION .
  • Page 4: General

    Before installing, verify that the type of gas supply (natural or propane) agrees with the specifications on the rating plate located on the front left side of the broiler. If the supply and equipment requirements do not agree, do not proceed with the installation. Contact your dealer or Vulcan-Hart Company immediately.
  • Page 5: Installation Codes And Standards

    Do not obstruct the flow of combustion and ventilation air. Adequate clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply of air in the room to replace air taken out by the ventilating system. Do not permit fans to blow directly at the broiler. Avoid wall-type fans which create air cross currents within the room.
  • Page 6: Testing The Gas Supply System

    A gas pressure regulator suitable for the V Series Heavy Duty Range battery application or single unit MUST be furnished by the installer or plumber at the time of installation. Connect the unit to 1 " pipe or larger. Check rating plate(s) for proper gas, gas pressure, and total BTU input for each application. The gas pressure regulator must have proper OUTLET PRESSURE and capacity for battery application.
  • Page 7: Operation

    OPERATION WARNING: THE BROILER AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE BROILER. CONTROLS Gas Valves — Regulate gas flow to the burners. Elevator Lever — Use elevator lever on the right to position the grill in relation to the burner heat. Grease Drawer —...
  • Page 8: Cleaning

    THE BROILER AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE BROILER. LUBRICATION All moving parts must be checked for wear and lubricated. Contact your local Vulcan authorized servicer. PILOT LIGHTS Pilot lights are to be kept clean and adjusted at the proper flame height.

This manual is also suitable for:

Vir seriesVrb36Ml-44953zVrb36cMl-44954zVrb36m ... Show all

Table of Contents