1.2.5

Environmental Condition


Temperature

Operating

Non-operating
Note) Storage should be within one month at 40°C and 120 hours at 60°C.

Humidity

Operating

Non-operating

Resistance to shock

Operating

Non-operating

Resistance to vibration

Operating

Non-operating
Note) 1. During non-operating, make sure that the head is capped.
2. During the transport, make sure that the head is capped and ink cartridge is installed to the
printer.
3. If the head is not capped at the power-off state, turn the power on with the ink cartridge
installed and turn off the power after confirming that the head is correctly capped.
4. Ink will be frozen under -4°C environment, however it will be useable after placing it more than
3 hours at 25°C.
Rev. A
:10 - 35•• (Refer to the figure below for condition)
:-20 - 60•• (with shipment container)
:20% - 80% RH
(without condensation. Refer to the figure below for condition)
:5% - 85% RH
(without condensation and with shipment container)
Figure 1-5. Temperature/Humidity of Range
:1G, within 1 ms (X,Y,Z directions)
:2G, within 2 ms (X,Y,Z directions/with shipment container)
:0.15G, 10•`55Hz (X,Y,Z directions)
:0.50G, 10•`55Hz (X,Y,Z directions/with shipment container)