EPSON Stylus Color 440/640/740

1.2.5 Environmental Condition


Temperature

Operating :10 to 35 °C (Refer to Figure 1-8 for condition)

Non-operating:-20 to 60 °C (with shipment container)
NOTE: 1 month at 40 °C and 120 hours at 60 °C

Humidity

Operating:
20% ~ 80% RH
(without condensation Refer to Figure 1-8 for condition)

Non-operating:
5% ~ 85% RH
(without condensation and with shipment container)
Humidity
(% RH)
80%
55%
20%
10
50
Figure 1-8. Temperature / Humidity of Range
Chapter 1
Product Description
Guaranteed
Area
27
35
( C )
95 ( F )
80

Resistance to shock

Operating:
1G, within 1 ms
X,Y,Z directions

Non-operating:2G, within 2 ms
X,Y,Z directions (with shipment container)

Resistance to vibration

Operating:
0.15G (Operating)

Non-operating:0.50G (Non-Operating)
NOTE 1:During non-operating, make sure that the head is capped.
NOTE 2:During the transport, make sure that the head is capped and
ink cartridge is installed to the printer.
NOTE 3: If the head is not capped at the power-off state, turn the power
on with installed ink cartridge and turn off the power after
confirming that Power on operation is completed and the head
is capped.
NOTE 4: Ink will be frozen less than -3°C environment, however it
will be usable after placing it more than 3 hours at 25°C.