Code
Error Messages
E-21
Area over
E-22
Area over
E-23
Area over
E-24
Area over
E-25
Area over
E-26
Area over
E-27
Area over
E-28
Area over
E-29
Area over
E-2A
Area over
E-2B
Area over
E-2C
Area over
E-2D
Area over
E-2E
Area over
E-2F
Area over
E-31
Area over
E-32
Area over
E-33
Area over
E-34
Area over
E-36
Area over
E-38
Area over
E-39
Area over
E-3C
Area over
Remove unused presser foot, or
E-40
it may be damaged
This function is not supported.
E-41
Turn off the power
E-42
ERROR 42
E-43
Slave I/F EEPROM read error
E-A1
Main(Z) motor lock
Main(Z) PCB temperature is too
E-A2
high
E-A3
Main(Z) motor voltage is too low
Main(Z) motor voltage is too
E-A4
high
Error
Hoop overhang(+X)
Hoop overhang(+Y)
Hoop overhang(+X, +Y)
Hoop overhang(-X)
Hoop overhang(+X, -X)
Hoop overhang(-X, +Y)
Hoop overhang(+X, -X, +Y)
Hoop overhang(-Y)
Hoop overhang(+X, -Y)
Hoop overhang(+Y, -Y)
Hoop overhang(+X, +Y, -Y)
Hoop overhang(-X, -Y)
Hoop overhang(+X, -X, -Y)
Hoop overhang(-X, +Y, -Y)
Hoop overhang(+X, -X, +Y, -Y)
Needle overhang(+X)
Needle overhang(+Y)
Needle overhang(+X, +Y)
Needle overhang(-X)
Needle overhang(-X, +Y)
Needle overhang(-Y)
Needle overhang(+X, -Y)
Needle overhang(-X, -Y)
The status of presser foot is issued as an alarm
when every second machine is used.
Invalid start-up error
XY movement error
Slave I/F EEPROM read error
Spindle motor lock
Main PC board temperature too high
Spindle motor voltage too low
Spindle motor voltage too high
BES-963BC • BES-1263BC

Chapter 9 Error code list

Measures
Pattern or the needle position is out of the embroidering area.
Reset the embroidering area on the panel or move the hoop to
the sewable position.
Thisected or when the bed is retreated (including when the power
is turned on). Remove the presser foot of the retreating head and
press the return key or turn on the F/B switch on the head to either
side. If every other head control is not selected or the bed is not
retreated, the bed sensor position may be faulty. Readjust it.
Turn the power off and on once.
Press the
or turn on the F/B switch on the head to either
STOP
side.
Turn the power off and on once. If the same error occurs
again, the main PC is faulty.
Press the
or turn on the F/B switch on the head to
STOP
either side.
If it occurs frequently, the main shaft
mechanism is faulty.
This is not usually displayed.