COZY HEDV254A Installation And Operating Instructions Manual page 8

Hi-efficient direct vent wall furnace

Advertisement

INSTALLATION
- CONTINUED
STEP3
a)
b)
c)
d)
INSTALLING
VENT
SYSTEM
5" - 32" WALL THICKNESS
(12.7 cm - 81.3 cm)
Use only factory supplied parts.
Do not attempt to modify in any way. To do so could cause a system
imbalance
resulting
in poor performance
and/or unsafe operating conditions.
Slide collection
box pipes through cutout and secure collection
box to inside wall. Anchors
(not supplied)
may be required.
(See Figure 5).
From outside house, mark collection
box pipes and cut off 1/2" beyond outside wall.
Slide vent cap pipes onto collection
box pipes and push in until flange is flush against house.
Secure vent
cap assembly
to outside wall with a slight downward
slope. This will prevent water from entering
and
allow condensation
to drain.
Caulk around the edges of the vent cap mounting
plate.
NOTE:
It may
be necessary
to build a metal or wood frame to provide
a flat surthce for the mounting
plate to be flush
against or to attain the 5" minimuln
wall thickness.
Trim Kit Brackets
Gas Inlet
Air Intake
,///--
Fine
Ontlet
(i49
cm)
HEDV25
- Figure
6
FIGURE 5
Trim Kit Brackets------.
Gas Inlet
--
Air Intake
.....
......
(i56
cm)
HEDV40
- Figure
6
Collection Box _,_
Assembly
Vent Cap
sembly
Vent Cap
Mounting
Plate
FIGURE
7
FIGURE
8
Page 8