CONTENTS OF KIT
1only
P/N 72532 2"x3" Steel Coupling
1only
P/N 41520 Center Bracket
1only
P/N 72575 2"x5' Black Flocked Tube
8 only
P/N 72593 2" Hose Clamps
1only
P/N72612 2"x6' Black Flex Tubing
1only
P/N72578 2"x3" Black Silicone
2 only
P/N 41515 Support Brackets
Wrapped Coupling
STEP 1 - LOCATE VENT OPENING
a)
Select location on outside wall that vent will exit through.
b)
Check outside f\3r proper clearances around vent cap. See installation instructions.
c)
Mark and cut 3-1/2" hole through both inside and outside walls, being sure to maintain level across both openings.
d)
Measure wall thickness. Mark and cut offboth intake and exhaust pipes to 1/2" beyond outside wall.
e)
Secure collection box to wall. Wall anchors, not provided, may be l"equired.
STEP2- INSTALLHEATER
a)
Select location on wall where heater will be installed.
b)
Using wall template supplied with heater, mark location for trim kit wall brackets.
c)
Attach brackets to wall (wall anchors, not provided may be l"equired) and back of heater. Using screws provided on
back of heater.
d)
Slide heater into position and secure brackets togehter. This should position back of heater 5" offwall.
e)
Select direction vent wil! exit trim kit, left, right, or straight up.
_)
Before installing trim kit remove knockout on this side.
STEP3 - INSTALLVENT
a)
Remove and discard P/N 72611 2"x24"blackflexmbingffomairinlet.
(Save hose clamp).
b)
Attach P/N 72612 2"x6' black flex mbing to air inlet. Secure with P/N 72593 2" hose clamp.
c)
Slide P/N 72575 2"x5' flocked robe through trim kit opening (knockout) and attach to P/N 72610 orange silicone
90, ,elbow supplied with heater. Secure with 2" hose clamp.
d)
Attach P/N 41515 support brackets to wall. Wall anchors, not provided, may be required. Postion support brackets
within 8" from side oftmn kit and end of pipe. Secure flex robing and flocked robe to brackets using 2" hose
clamps.
e)
Attach P/N 41520 center bracket 2-1/2' from pipe end and insert flex robe through bracket. This will prevent the
flex tube from touching the black flocked exhaust tube.
t)
Connect flex air intake robe and flocked exhaust tube to collection box.
g)
Complete gas connection and attach trim kit to brackets.
h)
Follow lighting instructions.
SPECIAL NOTES
a)
You may use up to three HEVK-5 Kits for a total of 15' vent extension with two additional elbows. DO NOT
EXTEND VENT BEYOND 15' OR USE MORE THAN THREE TOTAL ELBOWS (one elbow comes with the heater).
b)
To connect two vent kits together use P/N 72532 2"x3" steel coupling. Secure with 2" hose clamps.
c)
If you are using one, two, or three kits, after installation is complete you will discard 2 P/N 72593 hose clamps and
one P/N 72532 steel coupling.
d)
Ifyou need to make a 90..oft_et you wil! need to order P/N HEEL- 1 90..Elbow Kit. Two oft;ets require two kits.
e)
If complete vent extension is horizontal, pipes may be sloped down slightly to allow any condensate to
drain thlough the exhaust pipe to the outside. DO NOT ALLOW TO DRAIN ONTO WALKWAY. If any part of
vent extension is vertical or local codes do not allow draining of condensate to outside you must add P/N 18900
Condensate Kit.
_)
For cosmetic purposes, the addition of the HEVK-5 Kit can be enclosed by adding a HEVE-5 Vent Enclosure Kit.
To completely enclose the HEVK-5 Kit one HEVE-5 will be needed for each HEVK-5 used.
/
/
PN
72578
2"x3"
4N
41515
Black Silicone .f
Support
j"
Wrapped Coupling
Brackets
(2)
_-/_
,
PN
41520 j
//
(;enter Bracket
PN 72575
2"x5'
PiN 72612
2"x6'
Black
Flex Tubing
<e, is
72532
e only if connecting
flex tubing of 2 or
more ktis
Black Flocked
Tubs_
PN
72593
2" Hose Clamps