INSTALLATION
Failure to follow these instructions
carefilllv could result in poor performance,
property
damage, personal
injury, or
death.
STEP 1. LOCATE VENT OPENING
(Requires 3-112" diameter wall opening)
a)
Select area on wall where heater will be installed. Using template (packed with heater) mark shaded area
b)
c)
d)
e)
where hole can be cut and to locate
the wall
brackets.
(See Figure 4).
Locate studs on each side of this area.
Mark location for 3-1/2" diameter
hole between
studs. Hole should
be oft;et m miss studs. (See Fig. 4).
Check outside wall at this location for proper clearances
around vent cap. (See Fig. 1).
Cut vent openings
into both the inside and outside walls, being sure to maintain
level across both openings.
I __
[
L_l
g"
I
I
d
i I
Template
_L
b
It
Shaded
Area
j
Wall
Studs
II
16" O.C.
FIGURE 4
Manual ball valv_
must be above floor
V,?a 1 1 _.,,
Manual
shin offvalve
with
1/8" NPT plugged
tapping
Must be accessible
in room
where heater is installed _
./8 Blackiron pipe_.
Gas
Supply
Leg
j_
Back of
heater
FIGURE
5
STEP 2. ROUGH-IN GAS SUPPLY (See Figure 5)
Install at least _/8 gas supply line. Contact local gas supplier if any questions.
Install a drip leg in gas supply line immediately upstream from the gas connection to heater (see local codes),
and provide a 1/8" N.RT. plugged tapping, accessible for test gauge connection and an individual manual shut
offvalve accessible within room where heater is installed. (See Figure 5). The heater and its individual shut off
valve must be disconnected from the gas supply piping system during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5Pa). The heater must be isolated from the gas supply piping system by
closing its individual manual shut offvatve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5Pa). Test all connections for leaks using a soapy solution. NEVER
USE AN OPEN FLAME TO TEST FOR LEAKS.
The maxmmm
inlet gas supply pressure
for Natural
or L.P./Propane
gas is 1/2 p.s.i, or 14" w.c.
The minimum
inlet gas supply pressure
for the purpose
of adjustment
is 4.5" w.c. for Natural gas or 11.0" w.c. for
L.P./Propane
gas.
Page 7