Download Print this page

COZY HEDV254A Installation And Operating Instructions Manual page 11

Hi-efficient direct vent wall furnace

Advertisement

PROPER
BURNER
FLAME
The burner flame may be obse_wed by raising the sight
glass cover. A proper flame will have a dark blue inner
mantle, with a lighter blue outer mantle that extends from
the burner into tlle heat exchanger tube, (see Figure 10).
There is no primary air adjustment on the burner, and proper
flame is assured since the correct manifold pressure and
orificing have been done at the factory.
TO REMOVE
MAIN BURNER
FOR
INSPECTION
AND CLEANING
1.
Turn off all electrical supply to heater.
2.
Turn off gas supply.
3.
Remove front panel.
4.
Unplug wire to direct spark ignitor and sensor.
(See Fig. 11.)
5.
Disconnect vacuum hose from burner box.
6.
Remove screws holding burner box top to burner
box. (See Figure 11.)
7.
Remove burner plate and burner box top. Take
care not to contact, or strata _gmtor m any way
as it is extremely fragile. (See Figure 11.)
8.
Remove 2 nuts holding burner bracket. (See
Figure 11).
9.
Slide burners toward heat exchanger and lift up
from rear and back. (See Figure 11).
10.
Clean or replace as needed.
11.
Reinstall by reversing Steps 9 - 1.
BURNER
ORIFICE
Appliance
input ratings are based on sea level operation
and need not be changed
for operation
up to 2,000 feet
(609.9 m) elevation.
For operation at elevations above 2,000
feet (609.9 m).
The BTU input must be reduced
4% per 1,000 ft. See the
following
orifice chart for the proper orifice drill size for a
specific elevation.
SPECIFIC
ELEVATIONS
MODEL
0 to
2.000'
4,000'
6,000'
8,000' -
NO.
2.000'
4.000'
6.000'
8.000'
10.000'
NATURAL GAS
HEDV253A
51
52
52
53
54
HEDV403A
45
47
48
49
50
L.P. GAS
HEDV254A
58
60
62
63
64
HEDV404A
55
55
56
56
57
/Primary
Flame
FIGURE 10
NOTE:
THE FURNACE AND ALL COMPO-
NENTS MUST BE INSPECTED
AT LEAST
ANNUALLY BY A QUALIFIED SERVIC E PER-
SON.
THIS
SHOULD
INCLUDE
THE
BURNER, HEAT EXCHANGER,
AND VENT
SYSTEM.
BE SURE THAT THE FLOW OF
COMBUSTION
AND VENTILATION
AIR
ARE NOT OBSTRUCTED
AND THAT ALL
HOSES ARE
UNDAMAGED,
AND ALL
CLAMPS ARE SECURELY TIGHTENTED.
MaxitroI
Gas \Mve
Burner
Box Top
Burner
Bracket
Direct Spark Ignitor
Manifold
FIGURE 11
Page 11

Advertisement

loading

This manual is also suitable for:

Hedv253aHedv403aHedv404a