2.
.
CLEARANCES
RESIDENTIAL
GARAGE INSTALLATION:
Gas utilization equipment in residential garages
shall be installed so that all burners and burner ignition devices are located not less than ! 8 inches
(46 cm) above the floor. You must build a platform 18" above floor, the full width aa_ddepth of the
heatec including the rear trim ldt. HEATER
IS NOT DESIGNED
TO HANG ON WALL.
Unit
should be located or protected so it is not subject to damage by a moving vehicle. Use care in selecting
a good location within the garage. DO NOT locate the appliance where heated air will be directed
onto a nearby parked vehicle.
Paint may discolor or rubber may harden and crack. DO NOT allow
open or closed containers of paint, gasoline or other liquids having flmnmable vapors to be stored or
used in the same area as the heater.
LOCATION
The wall furnace must be installed on an outside wall, unless optional Kit No. HEVK-5 is used.
For most efficient performance,
locate furnace as centrally as possible in the area to be heated and
where occupants
may move about freely without coming into contact with the cabinet, and within
reach ofa l15V wall outlet.
If the furnace is installed in a basement,
a 12" clearance must be maintained
between ground level
and the bottom of the vent cap. Do not install furnace where vent cap will terminate
in a window
welt or any other opening below grotmd level. (See Figure 3). Do not allow snow accumulation to
build up within 12" of the vent cap.
OPTIONAL
KITS
HEVK-5 - To extend vent 5 foot from heater. This wilt allow vent cap to be installed above grade
from basement or to an outside wall. Atotal of 3 kits with 2 additional elbows may be used.
12"
Minimum above grade
without excavation
FIGURE
3