Download Print this page

COZY HEDV254A Installation And Operating Instructions Manual page 17

Hi-efficient direct vent wall furnace

Advertisement

MAINTENANCE
INSTRUCTIONS
For proper and sate operation
keep furnace and furnace area clean. At regular intervals
turn control valve to oft. let
cool and clean inside control and heat exchanger
compartment.
To clean front panel
use only a damp cloth, do not
use any kind of solvent or cleaning
fluid that could leave a residue to burn or give offfumes
when furnace is turned
on.
Have the furnace checked, cleaned,
and repaired
by a qualified
service person.
Check venting system,
and burner
operation
prior to use each year.
Follow a regular
service and maintenance
schedule
for sate and efficient
operation.
Do not obstruct combustion
and ventilation
air. Examine
the venting
system as a routine
part of the safety perfor-
mance check on an annual basis.
If the heat exchanger
is removed,
check the heat exchanger
intake gasket and draft inducer gasket and replace if
there is any sign of damage.
Be sure all gaskets
are in place when the heat exchanger
is replaced.
Failure to replace any gasket that has been damaged
may result in property
damage, personal
iniury or loss of life.
Oil the bearings
of the tan motor every 6 months with S.A.E. 20 oil.
SERVICE
RECORD