Kyocera ECOSYS FS-C8520MFP Operation Manual page 67

Fs-c8520mfp/c8525mfp operation guide
Hide thumbs Also See for ECOSYS FS-C8520MFP:
Table of Contents

Advertisement

Preparation before Use > Command Center RX (Settings for E-mail)
3
Item
Login Password
SMTP Security
POP before SMTP
Timeout
Test
E-mail Size Limit
Sender Address
Signature
Domain Restriction
Click [Submit].
When Other is selected for Authenticate, the password set here will be
used for authentication. The maximum length of the login password is 64
characters.
Enables or disables the SMTP Security. When this protocol is enabled,
either SSL/TLS or STARTTLS must be selected. To enable SMTP
security, the SMTP port may have to be changed according to the server
settings. Typically, 465 for SSL/TLS and 25 or 587 for STARTTLS are
well-known SMTP ports.
Set the amount of time to wait before time-out in seconds when you have
selected POP before SMTP as the Authentication Protocol.
Tests to confirm that the settings on this page are correct. When the Test
button is pressed, this machine tries to connect to the SMTP server.
Enter the maximum size of E-mail that can be sent in kilobytes. When the
value is 0, no maximum size is set.
Enter the E-mail address of the person responsible for the machine, such
as the machine administrator, so that a reply or non-delivery report will go
to a person rather than to the machine. The sender address must be
entered correctly for SMTP authentication. The maximum length of the
sender address is 128 characters.
Enter the signature. The signature is free form text that will appear at the
end of the E-mail body. It is often used for further identification of the
machine. The maximum length of the signature is 512 characters.
Enter the domain names that can be permitted or rejected. The maximum
length of the domain name is 32 characters. You can also specify E-mail
addresses.
2-27