Cable Connection To Lc Fiber-Optic Connectors - Enterasys SecureStack B2 B2G124-24 Hardware Installation Manual

Gigabit and fast ethernet switches
Table of Contents

Advertisement

Connecting to the Network
Figure 3-19
1 Mini-GBIC MT-RJ port connector
2 LC cable connector
3.
Plug the other end of the cable into the appropriate port on the other device. Some 
cables may be terminated at the other end with two separate connectors, one for each 
fiber‐optic strand. In this case, ensure that the transmit fiber‐optic strand is connected 
to the receive port and the receive fiber‐optic strand to the transmit port.
4.
Verify that a link exists by checking that the port Link/Activity LED is on (blinking 
green or solid green). If the Link/Activity LED is off, perform the following steps until 
it is on:
a.
b. If there are separate fiber‐optic connections on the other device, check the 
c.
d.
5.
Repeat steps 1 through 4, above, until all connections have been made.
3-30 Hardware Installation

Cable Connection to LC Fiber-Optic Connectors

Ã
Â
Verify that the device at the other end of the segment is ON and connected to the 
segment.
crossover of the cables. Swap the cable connections if necessary.
Check that the fiber‐optic connection meets the dB loss and cable specifications 
outlined in the Cabling Guide for multimode mode cabling. To obtain this 
document, refer to "Related Documents"  on page xvi. 
If a link has not been established, refer to Chapter
details. If a problem persists, refer to refer to "Getting Help" on page 1‐8 for 
details on contacting Enterasys Networks for support.
À
Á
3 Release tab
4 Link/Activity LED
4 for LED troubleshooting 

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents