Example 3
Shows the primary management module missing from slot 1. As long as the module 
installed in slot 2 is designated as a redundant management module, the module in slot 1 
can be removed without affecting system operation. However, if there is no module in 
slot 1, and the system is powered down, it cannot be restarted without a module in slot 1.
Rule: You cannot power up the system completely without a module in slot 1.
Example 4
Shows a chassis populated with 4xxxxx and 7xxxxx modules. DO NOT install 4xxxxx and 
7xxxxx modules in the same chassis. In a 4xxxxx system, the chassis must be dedicated to 
DFE modules only. The chassis will be rendered inoperable if any other type of module 
(DFE‐Platinum or legacy modules, for example) are installed in the same chassis with 
DFE‐Gold modules.
Rule: In a 4xxxxx system, the chassis must be populated with only 4xxxxx boards to 
operate.

Installing the DFE Module into a Chassis

To install a DFE module into a chassis, proceed directly to "Preparation" on page 3‐6 to 
start the installation process.
(Figure
3-1, C)
Caution: When installing a module into slot 1 of a non-operating chassis, it is strongly
recommended that the module have the desired version of firmware. Installation of a
replacement module into slot 1 of a non-operating chassis requires reconfiguration of the
system settings.
Precaución: Para instalar un módulo en la ranura 1 del chasis apagado, lo mejor es que
el módulo corresponda a la versión de firmware solicitada. Para instalar un módulo de
reemplazo en la ranura 1 del chasis apagado será necesario reconfigurar el sistema.
(Figure
3-1, D)
Caution: Failure to observe static safety precautions could cause damage to the
DFE module. Follow static safety handling rules and wear the antistatic wrist strap.
Do not cut the non-conductive bag to remove the module. Sharp objects contacting the
board or components can cause damage.
Precaución: Si no toma las medidas de seguridad necesarias para evitar descargas de
electricidad estática, es posible que el módulo se dañe. Siga los consejos de seguridad
para la manipulación del producto y no olvide utilizar la pulsera antiestática.
No corte la bolsa antiestática para sacar el módulo. Tenga en cuenta que si algún objeto
cortante entra en contacto con la placa o con los componentes, éstos podrían dañarse.
Enterasys Matrix DFE-Gold Series PoE Module Hardware Installation Guide 3-5