Connecting to the Network

Connecting UTP Cables to RJ45 Mini-GBIC Ports

The RJ45 Mini‐GBIC (MGBIC‐02) ports are10/100/1000 Mbps ports and have internal 
crossovers. When connecting a workstation to these ports, use a straight‐through cable. 
When connecting networking devices to these ports, such as a bridge, repeater, or router, 
use a crossover cable.
To connect twisted pair segments to the switch, refer to and proceed as follows:
1.
Ensure that the device to be connected at the other end of the segment is 
powered ON.
2.
Connect the twisted pair segment to the switch by inserting the RJ45 connector on the 
twisted pair segment into the RJ45 Mini‐GBIC.
3.
Verify that a link exists by checking that the Link/Activity LED is ON (solid green or 
blinking green). If the Link/Activity LED is OFF, perform the following steps until it is 
on:
a.
b. Verify that the device at the other end of the twisted pair segment is on and 
c.
d. Ensure that the twisted pair connection meets the dB loss and cable specifications 
4.
If a link is not established, contact Enterasys Networks. Refer to "Getting Help" on 
page 1‐6 for details.
Repeat all steps above until all connections have been made.
3-30 Hardware Installation
Note: RJ45 Mini-GBIC ports support Category 5 Unshielded Twisted Pair (UTP) cabling
with an impedance between 85 and 111 ohms. Category 3 cable may be used if the
connection is going to be used only for 10 Mbps.
Verify that the cabling being used is Category 5 or better with an impedance 
between 85 and 111 ohms with a maximum length of 100 meters (328 feet). 
properly connected to the segment.
Verify that the RJ45 connectors on the twisted pair segment have the proper 
pinouts and check the cable for continuity. Typically, a crossover cable is used 
between hub devices. A straight‐through cable is used to connect between 
switches or hub devices and an end user (computer). Refer to Figure
Figure 3‐17 for four‐wire RJ45 connections. Refer to Figure 3‐18 and Figure
for eight‐wire RJ45 connections.
outlined in the Cabling Guide. Refer to "Related Documents"  on page xvi for 
information on obtaining this document.
3‐16 and 