Problem 
Auger not turning 
  
  
Smoke smell or dust in 
house 
Room blower not operating 
  
  
Exhaust blower not 
operating 
  
  
Lazy Fire 
  
  
  
Blown Fuse 
  
  
High Pellet Consumption 
Squeaking Noise 
  
Pinging or Rattling Noise 
  
"E‐1" Code On Control Board  1. Vacuum bypass chip missing. 
Trouble­Shooting Guide 
Support at 1‐800‐245‐6489. 
Cause  
1. Bad auger motor. 
2. Foreign matter jamming 
auger. 
3. Vacuum sensor. 
1. Improper exhaust connection. 
1. Loose thermal sensor. 
2. Blower speed set higher than 
heat range, causing stove to cool 
and blower to cycle. 
3. Loose connection. 
1. Loose connection. 
2. Bad blower. 
3. Bad vacuum sensor. 
1. Bad exhaust blower. 
2. Excessive pellet moisture. 
3. Excessive ash build‐up. 
4. Low quality pellets. 
1. Power surge. 
2. Exposed wire. 
3. Electrical component shorting.  3. Check motors and blowers for 
1. Low quality or non‐uniformly 
sized pellets. 
1. Obstruction in auger tube. 
2. Blower Noise. 
1. Foreign material in blower. 
2. Loose exhaust fan set screw. 
Solution 
1. Replace auger motor. 
2. Remove pellets and object. 
3. Check exhaust blower. 
1. Check exhaust connections for 
leaks, especially the exhaust 
blower connect.  Seal leaks with 
silicone, aluminum tape or a hose 
clamp. 
1. Tighten connection on sensor. 
2. Lower blower speed. 
3. Check control board 
connection. 
1. Check control board 
connection. 
2. Replace blower. 
3. Replace vacuum sensor. 
1. Inspect and replace blower. 
2. Keep pellets dry. 
3. Thoroughly clean unit. 
3. Use only PFI premium pellets. 
1. Replace fuse; use surge 
protector. 
2. Check for exposed or frayed 
wire and loose connections. 
obstructions or short circuits. 
1. Use premium pellets or try 
another pellet brand. 
1. Check auger tube for foreign 
objects. 
2. Remove and oil blower. 
1. Check both blowers for 
material. 
2. Check set screw for tightness. 
1. Contact Technical Support. 
Page | 35