2.7.11
DATA OUT Connector
A data output interface may be used with either RS232 or
RS422 connector, as described below.
Table 2.12 DATA OUT Connector
Item
Connector type
Connector designation
Pin-outs
2.7.12
ALARM Connector
All units provide an alarm relay connector supplying a
summary relay. Under user configuration, it is activated
whenever the unit detects an alarm, or the power is
switched off.
Table 2.13 ALARM Connector
Item
Connector type
Connector designation
Pin-outs
EN/LZT 790 0005 R1A
Specification
9-way, D-type, female
DATA OUT
Pin
RS232
RS422
Pin 1
NC
HSD_CLK_A
Pin 2
TxD
NC
Pin 3
RxD
NC
Pin 4
NC
NC
Pin 5
NC
NC
Pin 6
NC
HSD_CLK_B
Pin 7
CTS
NC
Pin 8
(RTS)
HSD_DATA_A
Pin 9
NC
HSD_DATA_B
Specification
9-way, D-type, female
ALARM
Pin 1 – Relay 1, Normally Closed
Pin 2 – Relay 2, Common
Pin 3 – Relay 1, Common
Pin 4 – Relay 3, Common
Pin 5 – Relay 1, Normally Open
Pin 6 – Relay 2, Normally Closed
Pin 7 – Relay 2, Normally Open
Pin 8 – Relay 3, Normally Closed
Pin 9 – Relay 3, Normally Open