Cf_Coltemp Command; Cf_Offset- Command; Cf_Nzred Command - Sanyo PLC-WM5500/L - 5500 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-WM5500/L - 5500 Lumens:
Table of Contents

Advertisement

PLC-WM5500/WM5500L Expand Serial Command Functional Specifications
8.4.8

CF_COLTEMP Command

Command
"CF_COLTEMP_%1" [CR]
"000" ------------------------------ Xlow
"001"------------------------------- Low
%1
"002"------------------------------- Mid
"003"------------------------------- High
Set Color Temperature
The value set by this command will not be stored in the projector's memory.
Details
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Acceptable
Response
Unacceptable
8.4.9

CF_OFFSET- Command

Command
"CF_OFFSET-%1_%2" [CR]
"R" --------- RED
%1
"G" --------- GREEN
"B" --------- BLUE
"000-063"------ Directly specify value of Color selected in %1 of Offset.
%2
"UP"------------ Increment setting value of Color specified in %1 of Offset by 1
"DN"------------ Decrement setting value of Color specified in %1 of Offset by 1
Set value of Color specified in %1 of Offset (Available only in the normal Power ON
status)
Details
The value set by this command will not be stored in the projector's memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Acceptable
Response
Unacceptable

8.4.10 CF_NZRED Command

Command
"CF_NZRED_%1" [CR]
"OFF" ---------------- Cancel Noise Reduction
"ON" ------------------- Set Noise Reduction
%1
"UP" ------------------ Toggle between ON and OFF. (On→OFF→On→...)
"DN" ------------------ Toggle between ON and OFF. (On→OFF→On→...)
*"UP" and "DN" are exactly same operation.
Set Noise Reduction level (Available only in the normal Power ON status)
The value set by this command will not be stored in the projector's memory
Details
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It returns to the original setting in Suspend mode as well.)
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code"[CR]
"000" [CR]
"Error Code" [CR]
21/88

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wm5500Plc-wm5500/l