PLC-WM4500/WM4500L Expand Serial Command Functional Specifications
9.5.6
CR_DDOTS Command
Command
"CR_DDOTS" [CR]
Details
Get value of Display Dots
Acceptable
%1
Response
Unacceptable
9.5.7
CR_DLINE Command
Command
"CR_DLINE" [CR]
Details
Get value of Display Line
Acceptable
%1
Response
Unacceptable
9.5.8
CR_PCSTORE Command
Command
"CR_PCSTORE" [CR]
Get Free or Stored status of MODE1 - 10 in PC Adjust.
Details
Data consists of 10 bytes and each byte represents MODE1-10.
(F:Free, S:Stored)
Acceptable
Response
%1
Unacceptable
"000_%1" [CR]
"0100 – nnnn"
(nnnn = Total Dots – Position H)
"Error Code" [CR] ---- When command is not available in the
given condition (such as being selected input
"?" [CR] -------------------- When unknown command is received
"000_%1" [CR]
"0100 – nnnn"
(nnnn = Total Line – Position V)
"Error Code" [CR] ---- When command is not available in the
given condition (such as being selected input)
"?" [CR] -------------------- When unknown command is received
"000_%1" [CR]
"FFFFFFFFFF" ---------------- ALL Free
"SFFFFFFFFF" --------------- Mode1 is Stored, others are Free
:
"FFFFFFFFFS" --------------- Mode10 is Stored, others are Free
"SSSSSSSSSS" ------------- ALL Stored
"Error Code" [CR]
56/78