Status Read Command; Format; Transfer Example; Operation Condition - Sanyo PLC-WM4500/L - 4500 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-WM4500/L - 4500 Lumens:
Table of Contents

Advertisement

PLC-WM4500/WM4500L Expand Serial Command Functional Specifications
9

Status Read Command

9.1 Format

1)
PC issues commands in format as below:
"CR_ COMMAND" [CR]
Command: String
2)
When projector receives the appropriate command, it returns the required data as a string.
"000_" %1 [CR]
%1: Required Data (String)
3)
When the received data cannot be decoded, the projector returns "?" [CR]

9.2 Transfer Example

Get total dots of projector by Expand Serial Commands
PC → PJ: "CR_TDOTS" [CR]
PC ← PJ: "000_1344" [CR]

9.3 Operation Condition

1. Basically it should be always operated.
2. Status Read Commands are invalid when projector is in standby under Eco mode selected in
Standby mode menu
50/78

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wm4500Plc-wm4500/l

Table of Contents