Cf_Pipposition Command; Cf_Pipframelock Command; Cf_Pipstore Command - Sanyo PLC-WM4500/L - 4500 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-WM4500/L - 4500 Lumens:
Table of Contents

Advertisement

PLC-WM4500/WM4500L Expand Serial Command Functional Specifications

8.10.12 CF_PIPPOSITION Command

Command
"CF_PIPPOSITION_%1" [CR]
"POS1" -------------------- Move main picture position to up
"POS2" -------------------- Move main picture position to down
"POS3" -------------------- Move main picture position to left
"POS4" -------------------- Move main picture position to right
%1
"POS5" -------------------- Move sub picture position to up
"POS6" -------------------- Move sub picture position to down
"POS7" -------------------- Move sub picture position to left
"POS8" -------------------- Move sub picture position to right
Set position of "Picture in Picture". (Valid only when in the normal Power ON
status.) This function is worked from the first reception of Command.
* When setting beyond the area of movement is carried out, return Error Code
Details
"101" [CR] and the command is not executed.
Ex.1) When movement to right side has already reached limit; and "RIGHT" is
received.
*When "Picture in Picture" is set to Off, return "101" [CR]
Acceptable
Response
Unacceptable

8.10.13 CF_PIPFRAMELOCK Command

Command
"CF_PIPFRAMELOCK_%1" [CR]
"MAIN" -------------------- Set to main picture
%1
"SUB" --------------------- Set to sub picture
Set Frame lock of "Picture in Picture". (Valid only when in the normal Power ON
Details
status.)
Acceptable
Response
Unacceptable

8.10.14 CF_PIPSTORE Command

Command
"CF_PIPSTORE_%1" [CR]
"USER1"---- Store current setting status to User 1
"USER2"---- Store current setting status to User 2
%1
"USER3"---- Store current setting status to User 3
"USER4"---- Store current setting status to User 4
"USER5"---- Store current setting status to User 5
Store setting status of "Picture in Picture".
(Valid only when in the normal Power ON status.)
This command operates the same way as storing to User1-5 in "Picture in Picture"
Details
Menu.
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
40/78

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wm4500Plc-wm4500/l

Table of Contents