PLC-WM4500/WM4500L Expand Serial Command Functional Specifications

9.11.17 CR_FILTIMER Command

Command
"CR_FILTIMER" [CR]
Details
Get Filter used time
Acceptable
Response
%1
Unacceptable

9.11.18 CR_FILREPL Command

Command
"CR_FILREPL" [CR]
Details
Get status of Filter cleaning / replacement time
Acceptable
Response
%1
Unacceptable

9.11.19 CR_FANSPEED Command

Command
"CR_FANSPEED" [CR]
Details
Get selected Fan Control Speed mode.
Acceptable
Response
%1
Unacceptable

9.11.20 CR_SIMPLEMODE Command

Command
"CR_SIMPLEMODE" [CR]
Details
Get setting status of Simple mode.
Acceptable
Response
%1
Unacceptable
"000_%1" [CR]
"0600" ---------------------- Display massage by 600h used.
"0900" ---------------------- Display massage by 900h used.
"1200" ---------------------- Display massage by 1200h used.
"1500" ---------------------- Display massage by 1500h used.
"1800" ---------------------- Display massage by 1800h used.
"2000" ---------------------- Display massage by 2000h used.
"OFF" ---------------------- Off(Warning display is not displayed)
"Error Code" [CR]
"000_%1" [CR]
"1Y"-------Filter Exchange time is over value of Filter Message.
"1N"--Filter Exchange time is not over value of Filter Message.
"Error Code" [CR]
"000_%1" [CR]
"MAX" ------------------------ Max mode is selected
"NOR" ------------------------ Normal mode is selected
"Error Code" [CR]
"000_%1" [CR]
"ON" ------------------------ Simple mode is ON
"OFF" ---------------------- Simple mode is OFF
"Error Code" [CR]
70/78