INSTALLATION INSTRUCTIONS
(continued)
PREPARE THEOPENING (cent'd)
Flooring
Under
the Range
Your
range,
like
many
other
household
items,
is heavy
and
can
settle
into
sod
floor
coverings
such
as
cushioned
vinyl
or carpeting.
When
moving
the range on this
type of flooring,
it should
be
installed
on a 1/4
inch thick sheet of plywood
(or similar
material)
as follows:
When the floor
covering
ends at the front
of the
range,
the area that the range will rest on should
be built up with plywood
to the same level or
higher
than the floor covering.
This will allow
the range to be moved
for cleaning
or servicing.
STEP2
PREPAREFORELECTRICALCONNECTION
Use only a 3-conductor,
or if required
a 4-
conductor
range
cord set as noted
below.
These
cord sets are provided
with ring type terminals.
The electrical
rating of the cord must be 125/250
volts
minimum,
40 amperes.
NOTE:
Only a 4-conductor
cord is to be used
when
the appliance
is installed
in a mobile
home
or where local codes do not permit
grounding
through
the neutral.
STEP 3
1. Locate
connector
block at the bottom
rear of
range and remove
rear wiring
cover.
2. Directly
below the connector
block
is a hole
with a knockout
ring for accommodating
conduit
fittings.
Brackets
provided
are used
to support
the flexible
cord strain relief, which
must be
securely
attached
to the cord set.
WIRING
COVER
(SHOWN
REMOVED)
!f
\\
CONNECTOR
STRAIN
RELIEF
BRACKETS
RANGE
CORD
{PROV,DED
W,'"
SET
NOT
PART
OF
RANGEO)
POWER
'L__
"-_'<J_.,_, Z/
CORD
STEP4
3-WIRE SYSTEM
Power
Cord
Installation-Insert
screws
through
power cord terminals
so that
the screws
pass through
connector
block terminals
and
engage
nuts.
Tighten
screws
securely.
SCR EW----II
_
POWEF CORD
TERMINAL
POWER
CORD
CONNECTOR
......
/_,
MO w^c_) =
TERM'I11RL
_
"1"
Cable
Direct
Installation-Clamp
bare wires
between
the connector
block
terminals
and
movable
nuts with screws
tightened
securely.
1. Copper
Wiring
"__
_
SCREW
I,_
_
CONNECTOR
_-"
_-% _
BLOCK
TERMINAL
BARE
WIRE --tl,-
MOVABLE
FLEXIBLE
NUT _
CABLE
I
Connect
the neutral
or grounded
wire of the
supply
circuit
to the neutral
terminal
of the
connector
block,
located
in the center.
"]'he
power
leads
must be connected
to the outside
(brass
colored)
terminals.
M
!_
NEUTRAL
_-t_ JTERMINAL
!!
GROUNDING
STRAP
(GROUNDING
TO RANGE)
W_M_NING:
CONNECTOR
BI_CK
IS
APPROVED
FOR
COPPER
WIRE
CONNECTION
ONLY.
50