Positioning the Fireplace
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two (2) studs. This
will avoid any extra framing. All vent kit pipes should be assembled
on the unit after the unit is moved into the final position.
Cutting the Hole (Figure 23)
After the fireplace has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This hole
must be 12" (305 mm) high x 10" (254 mm) wide with its center
line determined by the amount of vertical rise and horizontal run of
the termination. See Figure 23. When locating the hole it must be
noted that the bottom of the cap must be 12" (305 mm) above the
ground level, and top of the cap must be no less than 18" (457 mm)
below a combustible projection, and no closer than 9" (229 mm) to
any wall running parallel to vent termination. See Figure 24.
25613-0-0309
10"
(254mm)
C
12"
B
V
H
C
B
A
CENTER OF ELBOW
STRAIGHT OUT
(MINIMUM)
Figure 23
"B"
"C"
5"
7"
(127 mm)
(178 mm)
5"
7"
(127 mm)
(178 mm)
"B"
"C"
5"
7"
(127 mm)
(178 mm)
5"
7"
(127 mm)
(178 mm)
Figure 24
MAXIMUM HORIZONTAL
RUN WITH NO VERTICAL
RISE AND 90° ELBOW
MAXIMUM HORIZONTAL
RUN WITH MINIMUM
VERTICAL RISE AND
90° ELBOW
8' (244cm)
TO BOTTOM
OF UNIT
Figure 25
VENT CAP
9" (229mm) minimum
TO SIDE WALL
3'
(914mm)
20' (6.1m)
PIPE STRAPS
EVERY 2' (61cm)
Page 17