All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround should be sealed with a non-
combustible material.
Hearth extensions are recommended, but not required for these fireboxes.
The firebox is designed to accept a 3/8-inch gas line for an approved
vent-free gas logset. Have the line installed by a qualified service
person in accordance with all building codes. Consult local building
codes to properly size the gas supply line leading to the 3/8-inch
hook-up at the unit. The state of Massachusetts requires that a
flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided on both sides of the firebox. See
Figure 11. On models with ceramic brick panels installed, carefully
remove the indented knockout in the ceramic brick panel using a
drill or utility knife. See Figure 12.
When installing optional ceramic fiber side panels into firebox,
lay panel on a flat surface. Remove the gas line knockout (round
depression) in the appropriate side panel using a drill or utility
knife.
After the brick panel knockout is removed, the firebox wrap may
have a round metal knockout that must be removed also. Use a
screwdriver to punch out the metal knockout.
Check gas type. Use only the gas type indicated on the gas log
set rating plate. If the gas listed on the plate is not your type of
gas supply, DO NOT INSTALL. Contact your dealer for proper
model.
Always use an external regulator for all LP fireboxes to reduce the
supply tank pressure to a maximum of 14" w.c. This is in addition
to the regulator fitted to the log set.
WA R N I N G : C O N N E C T I O N D I R E C T LY TO A N
UNREGULATED L.P. TANK CAN CAUSE EXPLOSION.
Install only a ANSI Z21.11.2 vent-free log set into this firebox.
Page 8
INSTALLING HOOD (continued)
VB4H36BL
VB4H36BR
VB4H36SS
VB4H36HP

GAS LINE CONNECTION

Standard Black
VB4H42BL
Polished Brass
VB4H42BR
Stainless Steel
VB4H42SS
Hammered Pewter
VB4H42HP
Standard Black
Polished Brass
Stainless Steel
Hammered Pewter
GAS ACCESS HOLES
Figure 11
Figure 12
23200-0-1206

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents