Empire Comfort Systems VFD32FB0L-1 Installation Instructions And Owner's Manual page 11

Deluxe vent-free universal fireboxes
Hide thumbs Also See for VFD32FB0L-1:
Table of Contents

Advertisement

OUTSIDE PLATE/VENT
SCREEN ASSEMBLY
OUTSIDE
HOOD
4" DIA. AIR DUCT
CONNECTOR
(INSTALLER SUPPLIED)
Figure 22
CAULKING
WALL
Caulk and Install Duct Termination
Figure 23
Figure 24
23200-0-1206
AIR DOOR
ASSEMBLY
FIREBOX OR
FIREPLACE
RAIN CAP
DUCT TERMINATION
Completion of Air Kit installation
1.
Determine the length of 4" Dia. rigid or flex duct connector
(installer supplied) you will need from the firebox/fireplace
to the exterior surface of the outside wall, where the air kit
hood will be installed. Add a few extra inches to the length
to allow for easier attachment of the outside duct connection
prior to securing the outside rain cap hood to the building.
2.
Secure the 4" dia. duct to the Air Door assembly collar on the
firebox/fireplace with band clamps or screws.
3.
Run the other end of the duct through the exterior wall cut-
out.
4.
From the outside of the building, connect the duct to the
collar on the outside air vent assembly with band clamp or
screws to secure.
5.
Mate the outside rain cap hood over the air vent, seal with
caulk as necessary, then secure with screws provided to the
exterior wall surface. See Figure 22 and 23.
Figure 24 illustrates the various options for installation of the
6.
air duct run possibilities.
Page 11