Console Troubleshooting Guide - Smooth Fitness CE-3.0DS Owner's Manual

Table of Contents

Advertisement

"C
T
ONSOLE
PROBLEM
POSSIBLE CAUSE
E1
No Motor signal
The Computer cannot
E2
make contact with the
IC Chip
No heart rate signal
after Body Fat testing
E3
result when in Body
Fat Program (P8)
Motor couldn't return
E5
to the initial setup
value/zero point
The Computer is
NOT receiving a
Pulse Signal
No Hand
Pulse Signal
or incorrect
The Computer is
Hand Pulse
receiving a faint or
Signal
intermittent Pulse
Signal
The Adaptor is not
plugged in (item
The LCD
Screen does
power supply from
not display
Adaptor)
anything
The Computer is
faulty
S
ROUBLE
HOOTING
SOLUTION
1. Motor Malfunction
2. Magnetic System
Malfunction or got stuck
3. Connection Wires are not
well-connected or broken
4. Console Malfunction
1. Disconnect the Adaptor or Batteries. Reconnect the Adaptor or Batteries to REBOOT
the system. Wait two minutes then verify that the system works correctly
2. If IC Chips is not well-assembled. Remove and reinsert the IC Chip
3. If the above solutions couldn't solve the problem, replace the IC chip with a New IC
Chip
If you do not place your hands on the Pulse Sensors correctly, the Pulse Sensors
won't be able pick up the signals. The console would then display an error message
"E3". To test it again, be sure to place your hands back on the Pulse Sensors correctly
1. Check whether the wires
are broken or well-connected
2. Check whether the motor is
broken (has struggle to adjust
the resistance and will make
an abnormal noise)
Verify that the Hand Pulse Sensor Wire Plugs are connected FIRMLY and correctly
The Hand Pulse Sensors will NOT operate correctly if your skin is extremely dry.
Moisten your hands with a little water and try again.
Grasp the Hand Pulse Sensors firmly and avoid moving your hands while exercising.
The computer will need a few seconds to detect and display your correct pulse rate. If
this does not work, try relaxing your grip on the Hand Pulse Sensors
Clean the Hand Pulse Sensors to ensure a good contact between your body and the
Pulse Sensors
The problem still exists, replace the Hand Pulse Sensors.
Check that the Adaptor is correctly connected to an electrical outlet and plugged into
the socket on the machine correctly
Replace the Computer
"
G
UIDE
Replace Motor
Replace Magnetic System/Flywheel
Check whether the wires are well-connected or replace the
broke wires with the new wires
Replace Console
Replace the broken wires with new wires or
re-connected the wires
Replace Motor
Replace Magnetic System