Service And Maintenance; Adjustments; Figure 2. Gate Restrictor Plate - Cornelius Remcor TJ45-A Operator's Manual

Ice/beverage dispensers with automatic ice filling from a remote icemaker source
Table of Contents

Advertisement

SERVICE AND MAINTENANCE

CAUTION: Disconnect power to dispenser before installing, removing or adjusting this kit.
INSTALL PLATE ON
STUDS AS SHOWN

FIGURE 2. GATE RESTRICTOR PLATE

ADJUSTMENTS

This dispenser is provided with a gate restrictor plate, installed in it highest position. This plate adjusts the rate
of ice flow from the dispenser. In applications using buckets, carafes or other large containers, the plate may be
removed entirely for maximum ice flow. For glasses and cups, the plate may be adjusted downward to reduce
the flow of ice. The best position depends on the type of ice being used and the size container and must be
found by trial and error. Adjustment is made by loosening the upper two ice chute retaining nuts, sliding the re-
strictor plate to the desired position and re-tightening the nuts.
6
90632

Hide quick links: