Advertisement

Quick Links

Service Manual
TEA URN
POST-MIX
BEVERAGE DISPENSER
IMPORTANT:
TO THE INSTALLER.
It is the responsibility of the Installer to
ensure that the water supply to the
dispensing equipment is provided with
protection against backflow by an air gap as
defined in ANSI/ASME A112. 1.2-1979; or an
approved vacuum breaker or other such
method as proved effective by test.
Water pipe connections and fixtures directly
connected to a potable water supply shall be
sized, installed, and maintained according to
Federal, State, and Local laws.
Part No. 312020000
December 7, 1993
Revised: July 8, 1994
Control Code A
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This Installation Manual must be read and understood before starting to install or operate this equipment.
IMI CORNELIUS INC; 1993-94
IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone (800) 238–3600
Facsimile (612) 422–3232
Printed in U. S.A.-94

Advertisement

Table of Contents
loading

Summary of Contents for Cornelius TEA URN

  • Page 1 December 7, 1993 Revised: July 8, 1994 Control Code A THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Installation Manual must be read and understood before starting to install or operate this equipment.  IMI CORNELIUS INC; 1993-94 Printed in U. S.A.-94...
  • Page 2: Table Of Contents

    ..SERVICE AND MAINTENANCE ... . FIGURE 1. POST MIX TEA URN ... . APPLICABLE WARNINGS, CAUTIONS AND FIGURE 2.
  • Page 3: General Information

    GENERAL DESCRIPTION This section provides a description, theory of operation, and design data for the Tea Urn Post-Mix Beverage Dispenser, hereinafter referred to as a Unit. UNIT DESCRIPTION The Unit (see Figure 1) is compact and intended for countertop installation.
  • Page 4 ADJUSTABLE ADJUSTABLE WATER FLOW CONCENTRATE REGULATOR FLOW REGULATOR WATER FILTER INSTALLATION FOR FILTERS WITHOUT BUILT-IN WATER SHUTOFF VALVE FILTER WATER SOURCE SHUTOFF SF‘–1 DISPENSING VALVE VALVE DISPENSER PRIMARY CO REGULATOR ASS’Y CYLINDER PRESSURE GAGE COUPLING GAS CHECK CONCENTRATE PUMP VALVE (SEE NOTE) NOTE: CONCENTRATE PUMP MAY ALSO BE DRIVEN BY NITROGEN...
  • Page 5: Installation

    Unit and front of dispensing Inspector to substantiate claim. File claim with the valve – Instructions for applying decals included. delivering carrier, not with IMI Cornelius Inc. 6. SERVICE MANUAL (item 6). A guide to UNPACKING AND INSPECTION installation, operation, and maintenance of the Unit.
  • Page 6: Installation

    A water shutoff valve and a water filter DISPENSING VALVE are recommended for use at the plain 1. Open shutoff valve in plain water source line. water source. IMI Cornelius Water Filter P/N 313860-000 and Quick Disconnect 2. Inspect connections for leaks. Set P/N 313867-000 are suggested.
  • Page 7: Operators Instructions

    OPERATORS INSTRUCTIONS This section describes the Unit’s operating control, ADJUSTING WATER-TO-SYRUP “RATIO” OF daily pre-operation checks, and maintenance DISPENSED PRODUCT procedures to be performed by the operator. Water-To-syrup “Ratio” of dispensed product should be checked periodically and adjusted if necessary. Refer to SERVICE AND MAINTENANCE section of this manual for adjustment procedure.
  • Page 8 supply should be checked daily and replenished if necessary. Refer to SERVICE AND MAINTENANCE section for instructions. CLEANING CO GAS CHECK VALVES The CO gas check valve must be inspected and serviced as instructed at least once a year under normal conditions and after any CO system servicing or disruption.
  • Page 9: Service And Maintenance

    SERVICE AND MAINTENANCE This section describes service and maintenance 3. Operate dispensing valve for exactly four procedures to be performed on the Unit. seconds. Approximately five ounces of water should have been dispensed. Make this measurement at least twice. IMPORTANT: Only qualified personnel should service internal components or electrical wiring.
  • Page 10: Pass Ass'y (Sf-1 Single Flavor Dispensing Valve)

    5. Place the ratio cup on a level surface and note WEEKLY CLEANING OF DISPENSING VALVE the concentrate and water levels. The The following dispensing valve cleaning instructions concentrate and water levels should be the are done without removing the valve from the Unit. same.
  • Page 11 6. Immerse concentrate line quick disconnect REPLENISHING CO SUPPLY connector in sanitizer. WARNING: CO Displaces Oxygen. Strict Attention must be observed in 7. Place waste container under dispensing valve. the prevention of CO (carbon dioxide) gas leaks in the entire CO and soft drink system.
  • Page 12 CAUTION: Do not puncture bag-in-box or it’s internal bag. 2. Open flap on new bag-in-box by rapping box sharply with palm of your hand. Do not use a sharp instrument to open the box. 3. Pull bag connector from inside the bag-in-box container, then remove dust cap from the connector.
  • Page 13: Troubleshooting

    TROUBLESHOOTING IMPORTANT: Only qualified personnel should service components. CAUTION: If repairs are to be made to CO , concentrate, or plain water systems, close CO cylinder shutoff valve, disconnect concentrate bag-in-box container, shut off plain water, and bleed systems pressures by operating the dispensing valve. Trouble Probable Cause Remedy...
  • Page 14: Only Water Dispensed

    Trouble Probable Cause Remedy ONLY WATER DISPENSED. Connections not secure on Secure connections on bag-in-box bag-in-box container. Container. Out of concentrate. Replenish concentrate supply as instructed. Concentrate pump primary Adjust primary CO gas regulator gas regulator not properly as instructed. adjusted.
  • Page 15 IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workman- ship under normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or Wilshire product, in your country, please write, fax or telephone the IMI Cornelius office nearest you.
  • Page 16 The Tea Urn Manual 312020-000 was revised. Removed all information in regard to a syrup tank hookup and made it only a bag-in-box hookup. This revised manual was never released on a PCN. Talked to George Murphy about this (08/11/94) and he said not to be in a hurry to release the revised manual as they have a rather large stock of old manuals in stock showing the syrup tank hookup along with the bag-in-box hookup which he said is no big deal.