Accel/Decel

Standard acceleration and deceleration is
linear. The inverter CPU can also calculate
an S-curve acceleration or deceleration
curve as shown. This profile is useful for
favoring the load characteristics in particu-
lar applications.
Curve settings for acceleration and decel-
eration are independently selected. To
enable the S-curve, use function A097
(acceleration) and A098 (deceleration).
Func.
Name /
Code
SRW Display
A097 Acceleration curve
selection
ACC LINE
A098 Deceleration curve
selection
DEC LINE
"A" Function
Description
Set the characteristic curve of
Acc1 and Acc2, two options:
00... linear
L
01... S-curve
Set the characteristic curve of
Acc1 and Acc2, two options:
00... linear
L
01... S-curve
L200 Inverter
Output
frequency

Accel. curve selection

Target
freq.
Linear
S-curve
0

Acceleration period

Run
Mode
–FEF
Edit
(EU)
00
00
3–27
A097 = 00
A097 = 01
t
Defaults