4.2.5.6 Removal of Carriage Motor

Perform steps 1 to 5 of Section 4.2.5.4.
1.
2. Disconnect the motor cable from the carriage motor. Disconnect the lead wire of the home-position sen-
sor from the molded clip at the bottom of the frame. (Refer to Figure 4-31.)
3. With a screwdriver, loosen the four tabs securing the carriage motor frame to the chassis frame. Remove
the carriage motor frame.
Tabs
4. Remove the belt tension spring from the carriage motor frame. Remove the E-type (3.2) retaining ring
on the carriage motor side; then remove the plain washer, belt pulley shaft holder, belt pulley, and timing
belt.
5. Remove the carriage motor by moving it in the direction shown by the arrow above.
LQ-510
Figure 4-31. Carriage Motor Frame Removal
Figure 4-32. Removal of Carriage Motor
DISASSEMBLY, ASSEMBLY, AND ADJUSTMENT
Retaining E-Ring (3.2)
Plain Washer
Bait Pulley Flange
Belt Pulley Shaft Holder
Carriage Motor Frame
Belt Tension
Spring
4-23