7.1.8 Condition and error messages

General information
DA220C V810
V820
A1
InF A1
InFo A1
A2
"StoP" flashes
+ Symbol
"cut-out"
A3
InF A3
InFo A3
A5
InF A5
InFo A5
Programming error messages (parameters)
If an incorrect code or parameter is entered, the following error message appears
(depending on the operating panel used):
DA220C
returns to "000" or the last parameter number
V810
returns to "0000" or the last parameter number
V820
as with V810, plus display "InF F1"
Hardware and software error messages
DA220C V810
V820
E2
InF E2
InF E2
E3
InF E3
InF E3
E4
InF E4
InF E4
h1
InF h1
InF h1
h2
InF h2
InF h2
34
Meaning
The pedal is not in its zero position
when the sewing drive is switched on
"StoP" flashes The cut-out is active
The reference position is not set.
For programming see sections 7.1.5, 7.2.7
and 7.3.8.
No valid Autoselect resistance has been
detected.
Emergency-operation function:
for information see section 6.8.2.
Meaning
Mains voltage too low or time between
main switch OFF and main switch ON too brief.
Machine blocked or not reaching the
required rpm
Control problem due to defective earthing
or faulty plug connections (contact faults).
The commutating-transducer lead is defective or
the power electronics that generate the
rotating field are faulty.
Processor faulty.