Correct the parameter value * if necessary, either with the "+" or "-" keys or by
turning the handwheel.
Press the "P" key twice to leave the programming level when the settings are
complete.
Check the positions: see section 6.7.
* NB:
The parameter values for positions 1E, 2E, 1A and 2A can be found in the parameter
sheet (accessory kit).
NB:
If position checking establishes that, for example, positions 1 and 2 deviate from the
required handwheel point by about the same angle, the problem can be solved by
altering the reference position by this angle.

7.2.8 Setting machine-specific parameters with the V810 operating panel

Machine-specific parameters can be set with the V810 operating panel. They are given
in section 7.1.6 and in the parameter sheet (in the accessory kit). The process is
described in section 7.2.6.

7.2.9 Master reset with the V810 operating panel

Any parameters that have been changed are restored to their pre-set values by a master
reset.
Turn off the main switch.
Press the "P" key, hold it down and turn on the main switch.
Release the "P" key.
Enter the technician-level code. See section 7.2.6.
Press the "E" key: the parameter "F-100" is displayed.
Press the "E" key: the value of parameter "F-100" is displayed.
Set the value to "170".
Press the "P" key twice.
Turn off the main switch.
After a brief pause, turn the main switch on again. All parameters except 111, 161,
170, 171 and 190 to 193 have been restored to their pre-set values.

7.2.10 Condition and error messages on the V810 operating panel

See section 7.1.8
40
CAUTION:
A few parameters, such as F-170 (reference position),
F-171 (needle position) and F-161 (direction of motor
rotation) are unaffected by a master reset.
After a master reset all machine-specific parameters
must be readjusted in accordance with the parameter
sheet. See section 7.2.8.