6.3 Fitting and connecting the sewing-light transformer (optional equipment)

Remove the mains plug.
Connect the mains cable of the sewing-light transformer to the mains-input side in
the control (see data sheet 9800 331101 DAT).

6.3.1 Connection to the DA220C control

1
Undo 4 screws on the front plate of the control.
Remove the front plate.
Push the cable forwards from behind through the cable conduit 2 into the control.
Remove the black rubber bushing 1.
Pierce the round opening in the rubber guide with a screwdriver.
Pass the cable of the sewing-light transformer through the resulting hole in the
rubber guide.
Replace the rubber guide.
Press on the terminal opening 5 or 6 with a small screwdriver to open terminal 3 or 4.
Connect the blue cable to terminal 3 and the brown cable to terminal 4.
Re-attach the front plate with the 4 screws.
20
CAUTION:
The sewing-light transformer is directly connected to the
mains. It is therefore live even when the main switch is
switched off.
The mains plug must be removed before carrying out any
work on the sewing-light transformer, e.g. changing the
fuse.
2
3
4
5
6